Specifications |
| Manufacturer |
EXTECH |
| Meter type |
digital multimeter |
| Type of display used |
LCD (4000) |
| DC voltage measuring range |
0,1m...400m/4/40/400/1000V |
| DC voltage measuring accuracy |
(1,2% + 2 digits) |
| AC voltage measuring range |
0,1m...400m/4/40/400/1000V |
| AC voltage measuring accuracy |
(2% + 5 digits) |
| DC current measuring range |
0,1΅...400΅/4000΅/40m/400m/10A |
| DC current measuring accuracy |
(1,5% + 3 digits) |
| AC current measuring range |
0,1΅...400΅/4m/40m/400m/10A |
| AC current measuring accuracy |
(2,5% + 5 digits) |
| Resistance measuring range |
0,1...400/4k/400k/4M/40MΩ |
| Resistance measuring accuracy |
(1,2% + 2 digits) |
| Capacitance measuring range |
0,001n...4n/40n/400n/4΅/40΅/100΅F |
| Capacitance measuring accuracy |
(3% + 5 digits) |
| Frequency measuring range |
0,001...10MHz |
| Frequency measuring accuracy |
(1,2% + 3 digits) |
| Temperature measuring range |
20...750°C |
| Temperature measurement accuracy |
(3% + 5?C) |
| Duty cycle factor |
0.1...99.9% |
| Duty cycle factor measurement accuracy |
(1,2% +2 digits) |
| Diode test |
0,3mA, 1,5V |
| Continuity test |
acoustic signal for R<100Ω |
| Sealing |
IP67 |
| Overall dimensions (W x D x H) |
82 x 55 x 182mm |
| Weight |
342g |
| Power supply |
1 battery 9V 6F22 |
| Conform to the norm |
EN61010 1000V CAT III, EN61010 600V CAT IV |
| |
Measuring instrument features:
- autoranging
- automatic power-off
- large, backlit LCD
- HOLD function
- MIN/MAX function
- REL function
- operates in extreme environemental conditions (dirt, dust, moisture)
- sealed enclosure prevents from water penetration
- diode and continuity test with buzzer
- overflow indicator
- resistant to a fall from 2m height
- low battery indicator
|
Standard equipment:
- soft cover
- test leads
- drop-like K-type temperature probe
|