Specifications |
| Manufacturer |
AXIOMET |
| Meter type |
insulation resistance meter |
| Type of display used |
LCD |
| Sampling |
2,5x/s |
| Test voltage |
1000VDC (for range 1M...4000MΩ), 125VDC (for range 0.125M...4000MΩ), 250VDC (for range 0.25M...4000MΩ), 500VDC (for range 0.5M...4000MΩ) |
| Resistance measuring range |
0,01...40/400Ω |
| Resistance measuring accuracy |
(1,2% + 3 digits) |
| Insulation resistance measuring ranges |
0,125M...4M/40M/400M/4000MΩ |
| Insulation resistance measuring accuracy |
(2% + 10 digits) |
| AC voltage measuring range |
1...750V |
| AC voltage measuring accuracy |
(1,2%+ 10 digits) |
| DC voltage measuring range |
1...1000V |
| DC voltage measuring accuracy |
(0,8% + 3 digits) |
| Continuity test |
acoustic signal for R<35Ω |
| Pollution degree |
2 |
| Operating temperature |
0...40°C |
| Storage temperature |
10...60°C |
| Body dimensions |
200 x 92 x 50mm |
| Weight with battery |
700g |
| Power supply |
6 batteries 1,5V LR6 (AA) |
| Conform to the norm |
EN61010 1000V CAT III |
| |
Measuring instrument features:
- autoranging
- automatic power-off
- bargraph
- large double backlit LCD
- HOLD function
- MIN/MAX function
- impact resistant holster
- continuity test with buzzer
- overvoltage protection
- measurement voltage blocking
- display zeroing function
- low battery indicator
|
Standard equipment:
- documentation
- test leads
- plastic case
|
|