Specifications |
Manufacturer |
KYORITSU |
Meter type |
digital multimeter |
Type of display used |
LCD 3,5 digit (3999) |
Bargraph |
33 segm. 50x/s |
Sampling |
2,5x/s |
DC voltage measuring range |
0...340m/3,4/34/340/600V |
DC voltage measuring accuracy |
(1,5% + 4 digits) |
AC voltage measuring range |
0...3,4/34/340/600V |
AC voltage measuring accuracy |
(1,5% + 5 digits) |
DC current measuring range |
0,1...100A |
DC current measuring accuracy |
(2% + 5 digits) |
AC current measuring range |
0,1...100A |
AC current measuring accuracy |
(2% + 5 digits) |
Resistance measuring range |
0,1...340/3,4/34k/340k/3,4M/34MΩ |
Resistance measuring accuracy |
(1% + 3 digits) (0,1...340kΩ), ±(15% + 5 digits) (34MΩ), ±(5% + 5 digits) (3,4MΩ) |
Frequency measuring range |
1...3,4k/10kHz (measurement with ACA current clamp), 1...3,4k/34k/340kHz (measurement with ACV test leads) |
Frequency measuring accuracy |
(0,1% +1digit) |
Continuity test |
acoustic signal for R<30Ω |
Input impedance for AC voltage |
10MΩ/V |
Body dimensions |
92 x 27 x 128mm |
Weight with battery |
220g |
Power supply |
2 batteries 1,5V LR03 (AAA) |
Conform to the norm |
EN61010 300V CAT III, EN61010 600V CAT II |
|
Measuring instrument features:
- auto and manual ranging
- automatic power-off
- HOLD function
- protection cover
- current clamp adapter
- universal
- DC - DCA zero adjustment
|
Standard equipment:
- batteries
- current clamp
- fixed test leads
|
|